EATON CHB Series Thermal Magnetic Circuit Breakers


Eaton CHB-Series thermal magnetic circuit breakers break the circuit in the event of short a circuits or overload.

Filter
StyleModelAic RatingAmpsNumber Of PolesVoltagePrice (ex. VAT)
A
CHB210
-102120/240V€203.27
B
CHB2125
----€1,048.80
C
CHB115
----€90.85
D
CHB160
----€199.51
E
CHB130
----€90.85
F
CHB140
----€100.79
G
CHB220
----€189.69
H
CHB215ST
----€1,765.90
H
CHB215
----€189.69
I
CHB2100
-----
RFQ
I
CHB2110
----€1,048.80
J
CHB270
-----
RFQ
K
CHB230
-----
RFQ
L
CHB9T2
----€28.66
M
CHB115GF
-201120/240V€274.95
N
CHB125
-251120V€100.79
O
CHB170
----€374.79
P
CHB110
----€90.85
Q
CHB120
----€90.85
R
CHB150
10kAIC@120V50A1120V€100.79
S
CHB250
10kAIC@240V50A2240V€207.82
T
CHB260
10kAIC@240V60A2240V€207.82
U
CHB280
10kAIC@240V80A2240V€734.22
V
CHB290
10kAIC@240V90A2240V€795.47
W
CHB3080
10kAIC@240V80A3240V€919.44
X
CHB3090
10kAIC@240V90A3240V€919.44
Y
CHB240
10kAIC@240V40A2240V€207.82
Z
CHB3100
10kAIC@240V100A3240V€919.44
A1
CHB320
10kAIC@240V20A3240V€734.22
B1
CHB330
10kAIC@240V30A3240V€734.22
C1
CHB340
10kAIC@240V40A3240V€734.22
D1
CHB350
10kAIC@240V50A3240V€734.22
E1
CHB360
10kAIC@240V60A3240V€734.22
F1
CHB370
10kAIC@240V70A3240V€795.47
G1
CHB315
10kAIC@240V15A3240V€734.22

Working Mechanism

  • In the normal state, these circuit breakers allow current to flow through the circuit.
  • In this case, the current-carrying contacts come into contact with one another.
  • When this device detects a ground fault, the contacts move apart and trip the circuit.

Features

  • Eaton CHB-Series thermal magnetic circuit breakers have standard box lug terminals to accommodate copper and aluminium wires of sizes 14 to 8 AWG.
  • Selected models have an internal common trip connection to operate all poles simultaneously.
  • They have a thermal-magnetic trip to avoid nuisance tripping during mild overloads but react instantly to severe short circuits.

Compatible Accessories

  • Eaton Load Centres: These units are useful for power distribution and circuit protection.

Standards and Approvals

  • UL

Frequently Asked Questions

What is the difference between a circuit breaker and a fuse?

A circuit breaker has an internal switch that trips when there is excess current, whereas a fuse is a metal piece that melts when the excess current overloads the circuit.

What is the interrupt rating of these circuit breakers?

10kAIC.

How to install these circuit breakers?

  • Remove the panel cover using a screwdriver.
  • Connect the neutral and ground wires.
  • Place the breaker inside and screw the cover back to the panel.