Vacuum Breakers | Raptor Supplies
We are closed from Monday, Dec 23rd and will reopen on Monday, Jan 6th. Any orders received during this time will be processed in the New Year.

Vacuum Breakers

Filter

Vacuum breakers are used in the chemical and pharmaceutical industries to prevent vacuum formation in a piping system. They allow air to enter the system when the pressure drops. Raptor...Read more

WATTS -

LF288A Series, Anti-Siphon Vacuum Breaker

StyleModelPrice (ex. VAT)
ALF288AC-1/2"€191.58
BLF288AC-3/4"€323.00
CLF288A-1/4"€149.04
CLF288A-3/8"€165.53
DLF288A-1/2"€124.37
DLF288A-3/4"€185.23
CLF288A-1"€286.81
BLF288AC-1/4"€150.31
ELF288AC-3/8"€201.34
BLF288AC-1"€452.76
WATTS -

LFNLF-9 Series Vacuum Breakers

StyleModelPrice (ex. VAT)
ALFNLF9 3/8€160.45
BLFCLFNLF9 3/8€167.11
ALFNLF9-HT 3/4€173.32
WATTS -

LFN9 Series Vacuum Breakers

StyleModelPrice (ex. VAT)
ALFN9-Z 1/4€259.64
BLFN9C 3/8€293.16
CLFN9C-M5 3/8€332.16
DLFN9C 1/2€597.65
WATTS -

LF800M4FR Series Vacuum Breakers

StyleModelPrice (ex. VAT)
ALF800M4FR 1 1/2€899.58
RFQ
ALF800M4FR 2€1,093.13
RFQ
BLF800M4FR 1/2€292.71
RFQ
CLF800M4FR 1 1/4€786.12
StyleModelPrice (ex. VAT)
A765-QT-PVB 1/2€196.10
RFQ
AU765-QT-PVB 1/2€221.66
RFQ
A765-QT PVB 3/4€136.73
RFQ
AU765-QT 3/4€200.35
RFQ
A765-QT PVB 1€154.64
RFQ
AU765-QT 1€220.56
RFQ
AU765-QT-PVB 1 1/4€735.41
RFQ
A765-QT-PVB 1 1/2€686.27
RFQ
AU765-QT-PVB 1 1/2€840.39
RFQ
A765-QT-PVB 1 1/4€669.81
RFQ
AU765-QT-PVB 2€943.96
RFQ
StyleModel
WATTS -

288A Series Vacuum Breakers

StyleModelPrice (ex. VAT)
A288A-Z39 1/2€121.54
B288A-MB 3/4€165.72
StyleModelPrice (ex. VAT)
A710 1 1/4€241.71
RFQ
A710 1€146.39
RFQ
A710 1 1/2€257.56
RFQ
A710 2€343.88
RFQ
StyleModelPrice (ex. VAT)
A9BD€685.18
A9BD-NPTMXFLARE€542.76
A9BD-NPTM 1/4€567.62
A9BD-NPTM 3/8€520.58
StyleModelPrice (ex. VAT)
ALF767FR 1 1/2€1,126.26
RFQ
ALF767FR 2€1,265.77
RFQ
ALF767FR 1/2€551.76
RFQ
ALF767FR 1€559.34
RFQ
ALF767FR 1 1/4€1,001.29
RFQ
ALF767FR 3/4€551.76
RFQ
WATTS -

S8 Series Vacuum Breakers

StyleModelPrice (ex. VAT)
AS-8C 1/2€111.17
BS-8 1/2€98.06
CS-8C 3/8€102.19
DS-8C-F€118.09
WATTS -

800M4FR Series Backflow Preventer Vacuum Breakers

StyleModelPrice (ex. VAT)
A800M4FR 1€217.05
RFQ
BU800M4-FR 3/4€341.14
RFQ
C800M4FR 1/2€254.51
RFQ
D800M4-FR 1 1/4€683.59
RFQ
E800M4-FR-SH 2€980.57
RFQ
E800M4-FR-SH 1€386.00
RFQ
F800M4-FR-SH 3/4€381.18
RFQ
G800M4-FR-SH 1 1/2€952.95
RFQ
B800M4-FR-QC 3/4€397.06
RFQ
H800M4-FR-QC 1€401.21
RFQ
I800M4-FR-QC 1/2€397.06
RFQ
J800M4-FR-SH 1 1/4€786.55
RFQ
WATTS -

LF8B Series, Hose Connection Vacuum Breakers

StyleModelPrice (ex. VAT)
ALF8B€39.32
BLF8BC€97.77
CLF8FR€110.97
StyleModelPrice (ex. VAT)
A3810101€47.07
A3810201€44.86
A3810301€58.06
A3810401€62.50
A3810501€119.66
A3810601€227.94
A3810701€242.16
A3810801€290.20
WATTS -

LF289 Series, Spill Resistant Vacuum Breaker

StyleModelPrice (ex. VAT)
ALF289-1/2"€370.09
BLF289-3/4"€753.69
WATTS -

Vacuum Breaker

StyleModelPrice (ex. VAT)
A8B€28.20
B8BC€53.05
C8BI€16.38
T&S -

Vacuum Breaker

StyleModelPrice (ex. VAT)
AB-0968€49.51
BB-0963€420.89
CB-0455-04-963VB€655.62
RFQ
D5PR-VB€88.80
EB-0977€306.42
FB-0975-GH€344.15
GB-0975€284.79
HB-0972€51.21
IB-0970-FE€76.73
JB-0970-01€130.45
KB-0965€145.93
LB-0929-A€168.03
AB-0969€73.24
MB-0929€221.53
NB-0458€581.91
OB-0457€617.62
PB-0456-04€296.99
PB-0456€261.55
QB-0455-M€1,761.94
OB-0455-04€293.35
OB-0455€261.55
R002849-40€158.20
S001301-45€159.41
TB-0456-04-963VB€659.12
CHICAGO FAUCETS -

Vacuum Breakers

StyleModelPrice (ex. VAT)
A892-GABCP€329.13
B892-ABCP€82.85
C892-402KJKABNF€48.84
D778-009KJKCP€276.45
E892-302KJKABNF€33.49
F892-254KJKCP€16.59
G734-105KJKNF€16.06
SLOAN -

Vacuum Breakers

StyleModelPrice (ex. VAT)
AV500AA€74.35
B323019€43.66
RFQ
B393055€84.32
RFQ
B393050€109.81
RFQ
B3301446€18.06
RFQ
B3301445€18.06
RFQ
B3301444€17.64
RFQ
B323112€22.57
RFQ
B323092€67.80
RFQ
B323063€55.61
RFQ
B323082€43.60
RFQ
B323036€44.43
RFQ
B323034€45.42
RFQ
B323003€34.76
RFQ
B393068€96.91
RFQ
B323210€39.06
RFQ
B805294€0.78
RFQ
B0323120PK€9.24
RFQ
CV600AA 3/4 X 9€45.81
B3396091€147.72
RFQ
B3396089€260.06
RFQ
B3396080€275.09
RFQ
B3396076€79.58
RFQ
B3396078€87.87
RFQ
B3396079€169.18
RFQ
WATTS -

Anti Siphon Vacuum Breakers

StyleModelPrice (ex. VAT)
ALF800M4QT 3/4€157.68
RFQ
B800M4-QT 1 1/4€613.13
RFQ
CLF800M4-QT 1 1/2€754.78
RFQ
DLF800M4QT 2€986.10
RFQ
ELF800M4QT 1/2€383.26
RFQ
FLF800M4-QT 1 1/4€776.85
G800M4-QT 2€789.29
RFQ
H288AC-MB€154.00
WATTS -

Atmospheric Vacuum Breakers

StyleModelPrice (ex. VAT)
ALF8AC€69.96
BLF8A€95.19
CLF8C€89.71
DLF8€78.76

Vacuum Breakers

Vacuum breakers are designed to prevent back-siphonage of water due to the generation of vacuum in water drainage systems. Raptor Supplies offers a wide range of vacuum breakers from brands like Apollo, Watts, Hayward, Wilkins, Morse, Plast-O-Matic, Sharkbite and Chicago Faucets. Apollo 38-100, 38-200, 38-500 and 38LF-100 Series vacuum breakers are ideal for a maximum pressure of 150 PSI and are available in 1/4 to 2 inch pipe sizes. The brand's 38-100 Series vacuum breakers prevent backflow of polluted water in portable water supply by breaking the vacuum generated during drainage of water. These ASSE 1001 certified breakers feature a heat-resistant silicone seat disc and a check valve with an air inlet. Watts ANSI, ASSE and NSF compliant vacuum breakers also have a maximum pressure withstanding rating of 150 PSI. These vacuum breakers are available in brass, bronze, chrome plated brass, lead free bronze, lead free brass and polished chrome body material variants.

Working Mechanism

  • Atmospheric vacuum breakers consist of a spring-loaded valve held closed by a diaphragm.
  • When a vacuum is detected, the diaphragm collapses to allow air to enter the piping system and break the vacuum.

Frequently Asked Questions

Where should a vacuum breaker be placed?

A pressure vacuum breaker should be placed a minimum of 12 inches above all downstream outlets and pipings.

How to maintain a vacuum breaker?

Periodically inspect the vacuum breaker for signs of wear / damage and replace it if necessary.

How to install a vacuum breaker?

  • Shut the water supply off and drain the system to remove the existing water.
  • Place the vacuum breaker as per the instructions and general codes & regulations.
  • Test the vacuum breaker to make sure that it is working properly.
  • Fill up the system by turning on the water supply again.

We are here to help!

Looking for a part not listed here?