EATON CH Series Standard Circuit Breakers | Raptor Supplies
We are closed from Monday, Dec 23rd and will reopen on Monday, Jan 6th. Any orders received during this time will be processed in the New Year.

EATON CH Series Standard Circuit Breakers


Eaton CH Series standard circuit breakers are installed in CH-type loadcenters for preventing electrical damage to connected devices due to excess current or short circuits. They have a plug-on type case for easy installation in loadcentres. These circuit breakers are generally HACR-rated for protecting equipment like receptacles, external motors and HVACs....Read more

Filter
StyleModelPrice (ex. VAT)
A
CHH2150H4X
€1,011.21
B
CH320ST
€553.83
C
CH325
€185.70
D
CH320SW
€136.57
E
CH320SWST
€1,170.44
F
CH320
€176.74
B
CH315ST
€1,421.71
G
CH315
€176.74
D
CH315SW
€199.63
H
CH330HID
€1,520.99
H
CH315HID
€1,520.99
I
CH3100
€334.52
B
CH3100ST
€1,440.96
J
CH310
€187.94
K
CH3090
€334.52
B
CH3090ST
-
RFQ
B
CH330ST
€553.83
L
CH345
€197.11
B
CH3080ST
€673.67
B
CH345ST
€1,421.71
M
CHH2175H4X
€1,370.38
M
CHH2100H4X
€1,011.21
B
CH360ST
-
RFQ
B
CH370ST
-
RFQ
N
CH370
€304.35
E
CH350SWST
€1,153.95
O
CH360
€187.94
B
CH350ST
-
RFQ
P
CH340
€187.94
Q
CH335
€197.11
R
CH330
€176.74
S
CH350
€187.94
B
CH340ST
€1,197.53
D
CH340SW
€170.01
K
CH3080
€334.52
T
CH280
€145.87
U
CH120
€50.12
V
CH2100
€421.16
W
CH2150X
€788.47
W
CH2125X
€1,468.36
X
CH2125N
€1,316.38
Y
CH2110CS
€1,011.14
X
CH2100N
€568.72
Z
CH2100ST
€613.82
A1
CH2125
€197.76
Z
CH2125ST
€1,854.94
W
CH2100X
€1,468.36
B1
CH2100CS
€537.12
C1
CH170ST
€815.42
D1
CH170
€180.07
C1
CH160ST
€690.91
E1
CH160
€58.23
F1
CH2125CS
-
RFQ
G1
CH2110
€334.52
Z
CH290ST
-
RFQ
H1
CH250M50
€63.33
I1
CH270
€134.53
J1
CH290
€173.50
Z
CH270ST
€1,148.15
Z
CH280ST
-
RFQ
H1
CH270M50
€150.08

Features

  • Eaton CH Series circuit breakers have a sliding handle with ON & OFF indication positions for easy identification of the breaker's status.
  • They have 1 / 2 / 3-poles for application-specific performance.
  • Their thermal-magnetic trip mechanism prevents nuisance tripping due to mild overloads while acting almost instantaneously during severe short-circuit conditions.
  • Eaton CH Series circuit breakers having more than one pole are equipped with an internal common trip connection for simultaneous operation of the poles.
  • They have a quick-make & quick-break switch mechanism for safe & efficient operation.
  • These circuit breakers require 3/4-inch (19.1 mm) space per pole for installation.
  • Selected models have a clamshell pack for enhanced durability, an MCB kit for easy installation on MCBs and a shunt trip for tripping the breakers remotely at any time.

Compatible Accessories

  • Eaton CHHT Handle Tie Bar: This handle tie bar with a moulded plastic handle cover can physically join the handles of adjacent CH type circuit breakers having a single pole.
  • Eaton CHPL Handle Lockoff: This is a padlockable device that locks the handle of escutcheon-mounted CH-type circuit breakers.
  • Eaton CHML Mechanical Interlock: It secures & locks 2, 3 & 4-pole CH type breakers.

Standards and Approvals

  • UL 489

Frequently Asked Questions

What is the voltage rating of these Eaton CH Series circuit breakers?

Eaton CH Series circuit breakers have a voltage rating of 120 / 240V and an interrupt rating of 10kAIC.

What are the points to inspect before operating these Eaton CH Series circuit breakers?

  • Remove the dust, dirt, grease, moisture or foreign contaminants from the unit.
  • Check that the unit's switch is free to move by switching the unit ON & OFF several times.
  • Inspect the unit for any cracks, chipping or discolouration. Tighten the terminals & connectors. Check the mounting hardware.
  • Remove any safety hazards near the installed area.

What wire gauges are suitable for wiring these Eaton CH Series circuit breakers?

  • #10-1/0 AWG
  • #14-2 AWG
  • #14-8 AWG

We are here to help!

Looking for a part not listed here?