TRIPP LITE Power Distribution Units | Raptor Supplies
We are closed from Monday, Dec 23rd and will reopen on Monday, Jan 6th. Any orders received during this time will be processed in the New Year.

TRIPP LITE Power Distribution Units


Tripp Lite power distribution units (PDU) having multiple outlets are ideal for distributing power to electronic devices like computers, servers & network switches inside a rack. They come in varying styles to offer basic power distribution to enhanced remote power management. These power distribution units enable adding more outlets to a UPS system, converting single high-ampere outlets to multiple low-ampere outlets and distributing the UPS / generator power to multiple outlets. They are further capable of hot-swapping any on-line UPS system, monitoring load l...evels while avoiding overloads, and remote controlling individual outlets.Read more

Filter
StyleModelPrice (ex. VAT)
A
PDUMH20HV
€291.96
B
PDUMH15
€177.31
C
PDUMV15
€200.57
D
PDUMV20
€269.12
RFQ
E
PDU1215
€154.62
F
PDU1220T
€223.97
G
PDU2430
€369.41
H
PDUV30HV
€451.30
RFQ
I
PDUMV30
€536.90
J
PDUMH20
€303.39

Features

  • Tripp Lite power distribution units (PDUs) mount either horizontally or vertically occupying 0 to 2U (rack units) of space.
  • Their mounting ears can be reversed for tool-less, front or rear-facing, rack-mount installation.
  • A front-panel digital load meter on selected models shows the total current output for local monitoring of connected loads and prevent overloading.
  • Selected power distribution units have a LX Platform network management card for enhanced remote management capabilities and monitoring information received from standard sensors like door-closure detectors, smoke alarms, temperature / humidity sensor.
  • Most PDUs further feature circuit breakers for protection against dangerous overloads & short circuits.
  • Hot-swappable power distribution units work together with the UPS system for keeping the system running around the year. They allow manual control of the PDU's input power source to replace equipment or do maintenance on them with no performance degradation.

Compatible Accessories

  • Tripp Lite ENVIROSENSE Remote Environmental Sensor: It measures humidity & ambient temperature on being installed on monitored / switched power distribution units. It can monitor & control alarms, security & telecom devices using contact closure communications.
  • Tripp Lite PDUSIDEBRKT Mounting Bracket: It allows vertical installation of selected power distribution units inside the brand's rack enclosures & open frame racks.
  • Color-Coded Power Cords With Adapters: Colour coding helps users to identify the right cord at a glance and prevent accidental disconnection of the wrong device.

Standards and Approvals

  • IEC
  • CE
  • UL

Frequently Asked Questions

What are the major types of power distribution units (PDUs)?

  • Basic PDUs: They offer AC power to multiple devices like a UPS system, generator or a utility power source.
  • Local Metered PDUs: They have digital load ammeters for local current monitoring, balancing loads and preventing overloads along with features of basic PDUs. Selected models come with Isobar surge protection to prevent surge damages.
  • Monitored PDUs: They feature a network interface for remotely monitoring & controlling outputs along with benefits of local metered PDUs.

What are switched power distribution units (PDUs)?

Switched PDUs come with all the features of monitored PDUs along with remote or local control of individual outlets. A switched PDU prevents costly sites as malfunctioning devices / outlets can be remotely rebooted and powered off or on.

How to operate Tripp Lite hot-swap power distribution units (PDUs)?

  • Plug the primary input of a selected into a UPS system.
  • Plug the hot-swap PDU's secondary input into the utility power outlet.
  • If the UPS requires offline maintenance or replacement, select the manual transfer switch in the hot-swap PDU for switching the connected load from the primary input to the secondary input.
  • After the UPS is repaired / replaced, return the PDU to the primary input.

We are here to help!

Looking for a part not listed here?