EATON GD Series Complete Molded Case Circuit Breakers, G Frame | Raptor Supplies

EATON GD Series Complete Molded Case Circuit Breakers, G Frame


Eaton GD Series moulded case circuit breakers reduce risks of damage by fault currents and fatal electrical shocks.

Filter
StyleModelAic RatingAmpsNumber Of PolesPrice (ex. VAT)
A
GD3100S1
----
RFQ
B
GD3045C
----
RFQ
C
GD3040D
---€1,538.92
C
GD3040DV
---€1,750.08
C
GD3040DA3
---€2,665.70
C
GD3040DS1
---€3,186.15
C
GD3040A3S7
---€3,839.47
C
GD3040DS101
---€3,004.65
B
GD3045A3
---€2,357.73
C
GD3040S1
---€3,119.86
B
GD3045S1
---€3,119.86
C
GD3040C
---€1,580.98
D
GD3050A3
---€2,303.98
B
GD3045D
---€1,464.46
D
GD3050A3G7
----
RFQ
E
GD3050DV
---€1,464.46
D
GD3050A3S7
---€3,839.47
E
GD3050DA3
---€2,357.73
E
GD3050CA3
---€2,234.57
E
GD3050C
---€1,580.98
C
GD3040A3
---€2,312.00
F
GD3035
---€584.21
E
GD3050D
---€1,515.22
G
GD3030D
---€1,464.46
G
GD3030A3
----
RFQ
H
GD3025S2
----
RFQ
G
GD3030A3S7
----
RFQ
H
GD3025D
---€1,609.87
H
GD3025DA3
---€2,278.74
G
GD3030DV
---€1,575.83
G
GD3030C
---€1,464.46
G
GD3030DVB3
---€2,105.15
G
GD3030DA3
----
RFQ
F
GD3035DA3
----
RFQ
G
GD3030DB3
----
RFQ
G
GD3030VFF01
----
RFQ
G
GD3030S1
---€3,227.98
G
GD3030V
---€1,756.41
G
GD3030S2
---€3,119.86
F
GD3035A3
---€2,383.82
F
GD3035C
---€1,464.46
F
GD3035D
---€1,464.46
I
GD3060C
---€1,429.75
I
GD3060A3
---€2,357.73
H
GD3025CA3
---€2,234.57
I
GD3090D1S3
---€3,610.66
J
GD3080A3S7
---€4,240.31
K
GD3090D
---€1,865.32
K
GD3090C
---€1,429.75
K
GD3090A3S1
---€4,219.78
K
GD3090A3
---€2,772.43
K
GD3090DA3
---€2,679.57
J
GD3080CA3
---€2,632.24
K
GD3090S1
---€3,596.42
J
GD3080S4
---€3,721.07
K
GD3090DS3
---€3,610.66
A
GD3100A3
---€2,761.00
A
GD3100DA3
---€2,679.57
A
GD3100G2
---€1,900.00
A
GD3100A3S7
---€4,240.31
A
GD3100D
---€1,865.32

Working Mechanism

  • Eaton GD Series moulded case circuit breakers feature fixed thermal and fixed magnetic trips to protect against faulty currents:

Fixed Thermal Trips

  • The thermal trip consists of a bimetallic strip which gets heated and bends when an overcurrent passes through the conductors, which opens the contacts and interrupts the current flow.

Fixed Magnetic Trips

  • The magnetic trip has an electromagnetic component that detects the presence of short circuits in a circuit.
  • As the current rises, a magnetic field is generated that trips the breaker and causes the contacts to open and stop the current flow.

Features

  • These units feature a fixed thermal and fixed magnetic trip unit to avoid nuisance tripping in mild current fluctuation but are highly sensitive to heavy inrush current, thus producing both instantaneous and time-delayed current limiting protection.
  • They have a compact, space-saving design that provides installation in tight spaces and allows for high-speed blow-open action, resulting in superior performance.
  • They are integrated with line and load side terminals for easy installation with panelboards and load centres.
  • These MCCBs also include a toggle and a mechanical latching mechanism that ensures the circuit breaker remains in the tripped position until it is manually reset.

Standards and Approvals

  • UL

Frequently Asked Questions

What is the advantage of moulded cases?

Moulded cases hold current-carrying components, trip devices and mechanisms integrated into one unit.

What is the purpose of a G-frame?

A G-frame is a modular design that provides a versatile and flexible platform to accommodate low-voltage circuit breakers. They also protect electrical systems from damage caused by overloads and short circuits, as well as mechanical stress.

What is the purpose of a toggle?

These circuit breakers come with an integrated over-centre toggle for visual indication of tripped status.

We are here to help!

Looking for a part not listed here?