EATON Circuit Breakers, CHB Series, Bolt-On Mount


Eaton circuit breakers (CHB Series) offer protection by cutting off electrical supply during short-circuit & overload occurrences. When combined with a mounting base, CHB breakers are also used for surface & DIN rail mount cable-in / cable-out applications. These CHB circuit breakers are availa...ble in 1, 2 and 3 pole options on Raptor Supplies.Read more

Filter
StyleModelAmpsNumber Of PolesPrice (ex. VAT)
A
CHB130GF
301€274.95
B
CHB220GF
302€584.70
B
CHB230GF
402-
RFQ

Circuit Breakers, CHB Series, Bolt-On Mount

Eaton circuit breakers offer protection by cutting off the electrical supply in the event of short-circuit and overload occurrences. They feature bolt-on mounting with line & load side lugs for hassle free installation. When combined with a mounting base, CHB breakers are also used for surface and DIN rail mount cable-in/cable-out applications. These bolt on circuit breakers feature a standard interrupting capacity of 10kA at 240V, ideal for reverse feed applications. They have a thermal-magnetic trip unit which provides both long-time & instantaneous trip functions and standard box lug terminals ideal for copper & aluminium wires. These bolt on circuit breakers are available in 1, 2 and 3 pole options on Raptor Supplies.

Working Mechanism

  • Eaton CHB Series circuit breakers normally allow current to flow. In this state, the current-carrying contacts come into contact with each other.
  • A ground fault can be caused by faulty wiring, damaged appliances or worn insulation.
  • When this device detects a ground fault, the contacts move apart, thus tripping the circuit.
  • After troubleshooting the issue, users can turn the circuit back ON by resetting it.

Features

  • The handles of these breakers are marked with ON/OFF indication & current rating.
  • They come with standard box lug terminals that are capable of accommodating copper and aluminium wire sizes ranging from 14 to 8 AWG.
  • They have a thermal-magnetic trip for avoiding nuisance tripping during mild overloads but reacting instantly to severe short circuits.
  • Selected models have an internal common trip connection to operate all poles simultaneously.
  • These units feature 5mA ground fault protection to prevent fatal electrical shocks caused due to overload and short-circuit occurrences.
  • They feature a bolt-on mounting system that is equipped with brackets for secure installation.

Compatible Accessories

  • Eaton CH Load Centres: These units are used to enclose CH circuit breakers for power distribution and circuit protection. They are available with buses rated 40 to 600A.

Standards and Approvals

  • UL 489

Frequently Asked Questions

Where can we use CHB Series Eaton circuit breakers?

These circuit breakers protect against high-frequency ground faults in heating, air conditioning and refrigeration equipment.

Are these units suitable for reverse feed applications?

These circuit breakers feature interrupting capacity of 10kA at 240V, making them ideal for reverse feed applications.

How to install a circuit breaker?

  • Remove the panel cover. Use a screwdriver to unscrew all four edges of the panel cover while holding it tight, to prevent it from slipping off.
  • Connect the neutral and ground wires.
  • Place the breaker inside.
  • Screw the panel cover back.

Does Raptor Supplies offer similar Eaton breaker variants with a higher amperage rating?

Yes, Raptor Supplies offers Eaton CHB230GF circuit breaker having an amperage rating of 500

We are here to help!

Looking for a part not listed here?