Uses
These compressed air powered fans offer a wide combination of features, making them useful for heavy duty operations in tanks, rails, granaries, underground utilities, mills & similar enclosed spaces that lack proper ventilation.
Features
Allegro Jet Fans:
- Allegro air jet fans have permanently sealed & lubricated, heavy-duty ball bearings for prolonged life.
- They are configured with nozzles that have the capacity to enable fan propulsion at speeds up to 11000 cfm, at pressure of 80 psig.
- These confined space fans ensure corrosion resistance in harsh environments, owing to their aluminium construction.
- These compressed air powered fans are equipped with side-mounted inlet connectors to provide input power connection.
- These spark resistant fans are designed for powerful air circulation.
Air Systems International Confined Space Ventilation Fans & Carts:
- These Air Systems International saddle vents come with a 90 degree elbow for supplying air.
- ASI confined space ventilation fans are supplied with galvanised steel constructed, confined space entry carts to provide mobility and storage for ventilation equipment or cylinders. They feature a maximum load capacity of 1200 lb.
- These confined space ventilation fan carts are configured with cabinet storage spaces and nylon bottle straps with steel safety chains for cylinder security. They are also equipped with standard or semi pneumatic wheels.
Americ Pneumatic Ventilation Fans:
- The design of these Americ pneumatic ventilation fans prevents dangerous sparking while delivering continuously circulating airflow in a limited space.
- They are configured with rugged dual wall shells that are created to be stackable for saving storage space.
- These polyethylene constructed, air powered fans comprise energy efficient, powerful pneumatic motors to redirect stale compressed air away from the main airstream.
Texas Pneumatic Tools Air Jet Fans:
- These four bladed air jet fans eject a high velocity of compressed air from the trailing edge of the fan blade and operate at pressures up to 110 psi.
- The bearings of these fans are lubricated enough to ensure prolonged life.
- The electro polished stainless steel fan guards guarantee supreme strength & corrosion resistance.
- They come with guide vanes to minimise turbulence and increase efficiency by smoothening air flow.
Standards and Approvals
Allegro, Texas Pneumatic Tools, Americ and Air Systems International offer confined space blowers or fans that meet OSHA, ANSI / API, UL & cUL, and AMCA 210 industry standards for environmental health, user safety and efficient performance of the blowers.
Frequently Asked Questions
Can a blower be placed vertically above a manhole?
Yes, confined space blowers can be placed above a manhole if it is supported safely, with proper ingress / egress, movement, vibration and weight mitigation.
What makes confined space fans unique?
Raptor Supplies offers confined space ventilation fans featuring -
- Motors which are built to last: These motors are designed to operate in the harshest of environments. Some fan models have totally enclosed motors that can minimise the possibility of debris build-up, thereby maximising life expectancy.
- Dual wall design - Large dents can not only produce rust spots, they can obstruct fan blade revolution as well, leading to costly repairs. Hence, dual wall shells and aluminium / polyethylene construction help prevent disturbances in airflow or internal mechanisms.
- Safety - These confined space ventilation fans are made in compliance with OSHA, ANSI / API, UL & cUL, and AMCA 210 industry standards to ensure safety and superior performance.
Is it better to positively ventilate or to evacuate air?
Any confined space must be positively ventilated, and should be evacuated when smoke is being generated in a specific location (for example, during grinding or welding operations).
What is the main difference between axial and centrifugal blowers?
Axial blowers feature internally housed motors that make them more portable & compact, as well as less expensive than centrifugal models. They offer higher airflow ratings in free air configuration than centrifugal blowers. Centrifugal variants, on the other hand, have the motor located outside the housing. The design of these blowers permits them to push against higher static pressure (greater dynamic back-pressure) with enlarged lengths of ducting, as compared to axial blowers.
Where should ventilation be directed in a confined space?
The ventilation equipment should be directed to the nearest entrance within the restricted space, to exhaust fumes and smoke.
What should the minimum oxygen level be in a confined space?
The minimum acceptable oxygen level in a confined space can be 15 to 19%, but that usually results in decreased ability to work and impaired coordination, thereby risking the health of workers. Hence, a confined space fan and blower play a vital role in creating a safe & hazard proof working environment for anyone who works in a small & enclosed area.