Ac Contact Rating | 1A @ 15V (Nc), 3A @ 15V (No), 3A @ 1V (Nc), 5A @ 1V (No) |
Application | Guard And Light Curtain Monitoring, Monitoring Antivalent Contacts For Emergency Stop, Monitoring Of Pressure-Sensitive 4-Wire Protective Devices |
Body Depth | 4 18/25" |
Body Height | 3.94" |
Body Width | 1.77" |
Dc Contact Rating | 1A @ 13V (Nc), 3A @ 13V (No), 3A @ 1V (Nc), 5A @ 1V (No) |
Delay Type | Adjustable |
Electrical Connection Type | Screw |
Environmental Protection | Dust, Splash Resistant |
For Use With | Emergency Stop, Guard Switch, Magnetic Switch, Npn Sensors, Pnp Sensors, Proximity Safety Switch, Rfid Safety Switch, Safety Light Curtain Or Sensing Mat/Edges |
Frequency | 50/60 Hz |
Input Voltage | 24V AC/DC |
Ip Rating | Ip20, Ip40, Ip54 |
Max. Operating Temp. | 185°F |
Min. Operating Temp. | -13°F |
Number Of Input Channels | 1 |
Number Of Inputs | 3 |
Power Consumption | 3 W |
Relay Mounting Style | Din Rail |
Response Time | 20 ms |
Safety Reliability Data | Dcavg >= 99% Conforming To Iso 13849-1, Hft = 1 Conforming To Iec 61508-1, Hft = 1 Conforming To Iec 62061, Mttfd > 30 Years Conforming To Iso 13849-1, Pfhd = 0.94E-09 Conforming To Iec 61508-1 For Ss0, Pfhd = 0.94E-09 Conforming To Iec 62061 For Ss0, Pfhd = 0.94E-09 Conforming To Iso 13849-1 For Ss0, Pfhd = 0.95E-09 Conforming To Iec 61508-1 For Ss1, Pfhd = 0.95E-09 Conforming To Iec 62061 For Ss1, Pfhd = 0.95E-09 Conforming To Iso 13849-1 For Ss1, Sff > 99% Conforming To Iec 61508-1, Sff > 99% Conforming To Iec 62061, Type = B Conforming To Iec 61508-1 |
Status Indicator | Led Indicator |
Time Delay | 0 sec. to 900 sec. |