Flat Shipping

Flat Shipping at €24.99 + VAT

REICHERT 13940015 Digital Refractometer Accuracy 0.3 Degree | AA7MAQ 16D202

REICHERT 13940015 Digital Refractometer Accuracy 0.3 Degree

Item: AA7MAQ Model: 13940015Cross Ref: 16D202
In Stock

Get it by Monday, Nov 18

Flat Shipping at 24.99 + VAT €24.99 flat shipping is applicable on orders with an aggregate weight less than 10kg. Orders exceeding 10kg will be charged default shipping rates.

€674.73 /unit
Add To Cart
Request a Quote

Payment Options Available

Delivery Options Available

Product Specifications:

ItemDigital Refractometer
Accuracy0.3 deg C Glycol, 0.003 SG battery elctrolyte, 1 deg C Windshield Fluid
Automatic Temperature CompensationY
FunctionFreeze Point Of Ethylene Glycol, Freeze Point Of Propylene Glycol, Battery Electrolyte Sg, Freeze Point Of Windshield Washer Fluid
Height1.06
Length3.9
Range0 deg to -57 deg C Ethylene Glycol, 0 deg to -51 deg C Propylene Glycol, 1.000-1.463 Battery Electrolyte SG, 0 deg to -54 deg C Windshield Washer Fluid
Resolution0.3 deg C Glycol, 0.003 SG battery elctrolyte, 1 deg C Windshield Fluid
TypeAutomatic Digital
Width2.13

Shipping Info:

Ship weight (kg) 0.225
Ship height (cm)4.32
Ship length (cm)14.99
Ship width (cm)8.38
HS code9027504015
Country of OriginJP

Product Details:

Reichert 13940015 Multi-Chek digital refractometer can help users measure the refractive index of liquids with utmost accuracy and precision. It is useful in automotive applications for checking coolant, battery and windshield fluids.

Features:

  • Reichert 13940015 digital refractometer includes a coolant tester that checks engine coolant freeze point EG and PG concentration.
  • Its automatic temperature compensation (ATC) delivers immediate, accurate and direct readings at ASTM D3321 standards of +/-1 degrees F and +/-0.55 degrees C.
  • This Multi-Chek refractometer's battery fluid tester conducts fast and easy tests of battery electrolyte, specific gravity and condition.
  • It can check the freezing point of windscreen fluid with a simple push button test.
  • This Multi-Chek instrument allows the user to switch between Celsius and Fahrenheit temperature units.
  • This digital refractometer has an IP65 rating, which makes it dustproof and resistant to low-pressure water jets from any direction.

Frequently Asked Questions:

Q. How to setup Reichert 13940015 digital refractometer?

A.

  • Insert the included batteries with the positive side (+) facing outwards.
  • Align the small mark on the battery cover with the mark on the instrument body, then insert the cover.
  • Rotate the cover clockwise until it reaches the desired position.

Q. When should you clean this digital refractometer?

A. Clean the measurement surface and well immediately following each sample reading.

Q. How should I clean the measurement surface and sample?

A. Cleanse with a mild soap and water solution or isopropyl alcohol, then rinse with distilled water.

Q. How do I clean the body of Reichert 13940015 digital refractometer?

A.

  • Use a soft cloth and a mild cleaning solution, such as a window cleaner.
  • Then, wipe the instrument dry.

Q. Are there any cleaning precautions I should be aware of?

A.

  • Avoid using harsh cleaning agents that could damage the instrument.
  • Do not use strong solvents, as they may deteriorate the prism seal and damage individual components.

Q. How do I calibrate Reichert 13940015 digital refractometer?

A.

  • Apply distilled water to the measurement surface.
  • Allow distilled water sample to temperature equilibrate with the instrument.
  • Press and hold the CAL key until CAL is displayed.
  • While holding CAL key, press the READ key.
  • Release both keys.
  • Successful calibration indicated by END display.

Q. How to change the fluid measuring type on this unit?

A. Press SCALE and then toggle between DOT4, DOT4 PLUS, EG FP, EG %, AdBlue%, Windshield washer fluid FP and Batt SG to change the reading mode scale.

Q. How does automatic temperature compensation work?

A.

  • Automatic temperature compensation is a process that adjusts readings for temperature changes. For example, if a sample is taken at a temperature outside the normal range for the instrument, the reading is corrected to a reference temperature of 20°C. This is important because the refractive index of a substance changes as the temperature changes.
  • It is worth noting that temperature compensation is not a substitute for controlling the temperature of the sample and the measuring surface. For this feature to work effectively, it is necessary to allow the sample to equilibrate to the ambient temperature of the measuring surface. Failure to do so will result in less accurate readings since the sample will be in a state of temperature and refractive index change.

Product Variants

ProductModelAccuracyFunctionRangeResolutionPrice
REICHERT 13940013 Digital Refractometer Accuracy 0.1 | AA7MAN 16D199 139400130.1Diesel Exhaust Fluid, Known As Def/Adblue/Arla/Aus320.0-50.0 Diesel Exhaust Fluid (Urea)0.1€604.39
REICHERT 13940014 Digital Refractometer Accuracy 0.5 Degree | AA7MAP 16D201 139400140.5 deg F Glycol, 0.003 SG battery electrolyte, 2 deg F Winshield FluidFreeze Point Of Ethylene Glycol, Freeze Point Of Propylene Glycol, Battery Electrolyte Sg, Freeze Point Of Windshield Washer Fluid32 deg to -70 deg F Ethylene Glycol, 32 deg to -60 deg F Propylene Glycol, 1.000-1.463 Battery Electrolyte SG, 32 deg to -65 deg F Windshield Fluid0.5 deg F Glycol, 0.003 SG battery electrolyte, 2 deg F Windshield Fluid€648.31
REICHERT 13940016 Digital Refractometer Accuracy 5 Degree Fahrenheit | AA7MAR 16D203 139400165.0 deg FDot3 And Dot4 Brake Fluid250 deg to 500 deg F DOT3, 250 deg to 570 deg F DOT3 HT, 257 deg to 527 deg F DOT4, 302 deg to 527 deg F DOT4 Plus5.0 deg F€607.03
REICHERT 13940017 Digital Refractometer Accuracy 5 Degree Celsius | AA7MAT 16D204 139400175.0 deg CDot3 And Dot4 Brake Fluid121 deg to 260 deg C DOT3, 121 deg to 299 deg C DOT3 HT, 125 deg to 275 deg C DOT4, 150 deg to 275 deg C DOT 4 Plus5.0 deg C€591.32

Explore Products

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

REICHERT 13940015 Digital Refractometer Accuracy 0.3 Degree
€674.73 /unit