We use cookies and similar tools necessary to enable you to make purchases and enhance your shopping experiences. We also use them to understand how customers use our services (for example, by measuring site visits) so we can make improvements. You can read our Cookie Policy for more information.
Strictly Necessary Cookies
Always Active
These cookies make our website work. They include logging personal details, like login/sign-up or account data, browser information, images & videos, and shopping cart journey.
In addition, we use optimisation cookies to test new features and designs on our website. The information collected helps us improve our website and our customers' experience.
Advertising
These cookies are used to understand the performance and relevancy of our adverts, to provide you with personalised adverts on other websites and social media, to track when you have arrived at our site from a recognised third-party affiliate website, and to track if you made a purchase based on the adverts we displayed to you.
Recommendations
These cookies enable us to provide personalised product and content recommendations, to make the browsing experience more relevant to you.
Functionality
These cookies are used to offer customer surveys and feedback, to improve search results, and to allow you to share content from our website on social media.
Analytics
These cookies help us improve our website by collecting and reporting information on how you use it.
Flat Shipping at 24.99 + VAT€24.99 flat shipping is applicable on orders with an aggregate weight less than 10kg. Orders exceeding 10kg will be charged default shipping rates.
Fuji Electric FRN0020C2S-2U variable frequency drive optimises energy consumption by adjusting the frequency and voltage supplied to the motor, contributing to increased operational efficiency. It is ideal for fans, pumps, conveyors and other machinery where precise motor speed control is essential.
Features:
Fuji Electric FRN0020C2S-2U variable frequency drive has a dynamic torque vector control for precise power calculation based on motor load.
It has adjustable acceleration and deceleration times from 0 to 3600 seconds for precise speed control.
This variable frequency drive offers a wide output frequency range from 0.1 to 400 Hz, accommodating diverse industrial applications.
It is equipped with a brake chopper for efficient braking during deceleration.
This variable frequency drive has an open enclosure with an overall compact design (5-1/2 inches) suitable for various installations.
It has a built-in protection mechanism against external alarm input, ground fault, overcurrent and overheating.
This variable frequency drive compliance with international standards (CE, EN61800-5-1, UL 508C) ensures reliability and safety.
Compatible Accessories:
Fuji Electric AC Drive NEMA 1 Kit: This NEMA 1 enclosure prevents dust and incidental contact with the VFD, making it suitable for indoor applications. By seamlessly integrating with the VFD, this kit ensures a streamlined and reliable solution for motor speed control, contributing to efficient and optimised operations in industrial settings.
Frequently Asked Questions:
Q. How to maintain this variable frequency drive?
A.
Visually inspect all components showing excessive heating or discolouration due to corrosion / oil leaks.
Clean the accumulated dust & debris using dry compressed air.
Check the torque settings of connectors. Don't over-torque the connections.
Set the replacement schedule for components with short life cycles.
Q. How do I troubleshoot variable frequency drives?
A.
Check for loose connections.
Check for overheating.
Check for proper voltage & current levels.
Q. How does the dynamic torque vector control feature of the FRN0020C2S-2U contribute to motor performance?
A. Dynamic torque vector control calculates and adjusts power based on motor load, optimising torque for improved overall motor performance.
Over breaking, Overvoltage, Under voltage, Motor Thermal Overload, Drive Thermal Overload, Phase to Phase or Phase to Ground Short Circuit, Phase Failure
Over breaking, Overvoltage, Under voltage, Motor Thermal Overload, Drive Thermal Overload, Phase to Phase or Phase to Ground Short Circuit, Phase Failure
Over breaking, Overvoltage, Under voltage, Motor Thermal Overload, Drive Thermal Overload, Phase to Phase or Phase to Ground Short Circuit, Phase Failure
Over breaking, Overvoltage, Under voltage, Motor Thermal Overload, Drive Thermal Overload, Phase to Phase or Phase to Ground Short Circuit, Phase Failure
Overload, Overvoltage, Under voltage, Input phase loss, Overheating, Short-circuit, Ground fault, Motor overload, DB resistor overheating, Stall prevention, Output phase loss, Motor protection by PTC thermistor, Auto reset
Overload, Overvoltage, Under voltage, Input phase loss, Overheating, Short-circuit, Ground fault, Motor overload, DB resistor overheating, Stall prevention, Output phase loss, Motor protection by PTC thermistor, Auto reset