Eaton Ed3150 | 46mw66 | Molded Case Circuit Breaker, 3-pole, 150 A, 240vac, 125 Vdc, 65 Kaic At 240vac, 50/60 Hz | Raptor Supplies
EATON ED3150 Bolt On Circuit Breaker Ed 150 Amp 240vac 3p 65kaic@240v | AG8MUT

EATON ED3150 Molded Case Circuit Breaker, 3-Pole, 150 A, 240VAC, 125 Vdc, 65 Kaic At 240VAC, 50/60 Hz

Item: AG8MUT Model: ED3150Cross Ref: 46MW66
In Stock : 58 Units

Get it by Friday, Feb 7

€904.74 /unit
Add To Cart
Request a Quote

Payment

Delivery

Product Specifications:

ItemCircuit Breaker
AIC Rating65kAIC@240V
Amps150A
Frame TypeED
Number of Poles3
Voltage240V
Voltage TypeAC

Shipping Info:

Ship weight (kg) 2.025
Ship height (cm)10.49
Ship length (cm)8.59
Ship width (cm)10.49
Country of OriginUS

Product Details:

Eaton ED3150 moulded case circuit breaker with F-frame provides overcurrent protection and safe switching in DC & AC systems.

Features:

  • Eaton ED3150 circuit breaker can accommodate 4 to 4/0 AWG wires.
  • This breaker features non-interchangeable thermal & magnetic contacts for long-time and instantaneous protection.
  • It has a 150A current rating and a maximum interrupting capacity of 65kAIC.
  • This circuit breaker features 3-pole, 3-phase configuration for high-speed blow open action.
  • It is equipped with bolt-on load side lug terminals for secure connection.

Standards and Approvals:

  • CSA
  • UL

Frequently Asked Questions:

Q. What is the difference between MCBs and MCCBs?

A.

  • MCBs protect items from current overloads while MCCBs protect equipment from fault currents & excess temperature rise.
  • The tripping circuit of MCBs is fixed while MCCBs have a movable tripping circuit.
  • MCBs have comparatively low interrupting ratings than MCCBs.

Q. What causes moulded case circuit breakers to trip?

A. Overloading of a circuit is the main reason that leads to frequent short-circuit tripping.

Q. What to check before operating Eaton ED3150 circuit breaker?

A.

  • Remove dust or moisture from the surface of the circuit breaker with a vacuum or cloth. Do not blow debris into the circuit breaker.
  • Switch to ON and OFF multiple times to ensure that the mechanical linkages are free.
  • Check base, operating handle and cover for any cracks, discolouration & chipping.
  • Check connectors and terminals for signs of overheating and looseness.
  • Check the mounting hardware and the area where it is installed.

Product Variants

ProductModelAic RatingAmpsFrame TypeNumber Of PolesVoltagePrice
EATON ED2200 Bolt On Circuit Breaker Ed 200 Amp 240vac 2p 65kaic@240v | AG8MTQ ED220065kAIC@240V200AED2240V€676.68
EATON ED3100 Bolt On Circuit Breaker Ed 100 Amp 240vac 3p 65kaic@240v | AG8MUP ED310065kAIC@240V100AED3240V€2,177.66
EATON ED3125 Bolt On Circuit Breaker Ed 125 Amp 240vac 3p 65kaic@240v | AG8MUR ED312565kAIC@240V125AED3240V€904.74
EATON ED3175 Bolt On Circuit Breaker Ed 175 Amp 240vac 3p 65kaic@240v | AG8MUU ED317565kAIC@240V175AED3240V€904.74
EATON ED3200 Bolt On Circuit Breaker Ed 200 Amp 240vac 3p 65kaic@240v | AG8MUV ED320065kAIC@240V200AED3240V€904.74
EATON ED3225 Bolt On Circuit Breaker Ed 225 Amp 240vac 3p 65kaic@240v | AG8MUW ED322565kAIC@240V225AED3240V€904.74
EATON EHD1050 Bolt On Circuit Breaker Ehd 50 Amp 277vac 1p 14kaic@480v | AG8NCA EHD105014kAIC@480V50AEHD1277V€248.83

Explore Products

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

EATON ED3150 Molded Case Circuit Breaker, 3-Pole, 150 A, 240VAC, 125 Vdc, 65 Kaic At 240VAC, 50/60 Hz
€904.74 /unit