EATON BR4242B400R Main Circuit Breaker Loadcenter, 400A, 42 Circuits, Single-Phase

Item: BJ7TCY Model: BR4242B400R
Limited Availability

Due to weight and dimension restrictions, please request a shipping quote

€5,006.88 /unit
Request a Quote

Payment Options Available

Delivery Options Available

Product Specifications:

ItemLoad Center

Shipping Info:

Ship weight (kg) 46.35
Ship height (cm)20.32
Ship length (cm)176.53
Ship width (cm)49.53
Country of OriginUS

Product Details:

Eaton BR4242B400R main circuit breaker load center is designed to distribute utility-supplied electricity throughout the building for feeding all branch circuits. The circuit breaker located in the load center protects each branch circuit.

Features:

  • This load center can protect against ground and arc faults by employing specialty or electronic circuit breakers.
  • It can be mounted in or against a wall.
  • The NEMA type 3R enclosure protects against rain, sleet & damage from external ice formation.

Compatible Accessories:

  • Eaton BR Circuit Breakers: These circuit breakers feature diagnostic trip codes for complex occurrences. Their short-body design maximises space inside the load center by adding wire-way and gutter space for easy installation.

Standards and Approvals:

  • UL
  • CSA
  • NEC

Frequently Asked Questions:

Q. How to install Eaton BR4242B400R load center?

A.

  • Remove the knockouts needed to install cable clamps or conduits.
  • To fasten the enclosure to the wall, align and level it with removable nails or screws inserted through keyholes at the top and bottom.
  • Place the enclosure between the studs.
  • Both sides of the enclosure are provided with 3/8-inch (17.1 mm) and 1/2-inch (12.7 mm) drywall scribe markings to aid when flush mounting.
  • Oval knockouts are provided on each side of the enclosure for mounting. Remove the knockout and insert a nail or screw through the oval opening.
  • Connect the main and neutral wires. Torque the wire pressure screws to the value indicated on the main label on the inside of the door.
  • Install BR branch circuit breakers by sliding the breaker's foot under the back pan rail and pushing the breaker onto the bus stab.
  • Connect the branch circuit wire to the circuit breaker's load end. Tighten the wire pressure screw to the torque value listed on the load centre enclosure.
  • Remove only the twist-outs that correspond to the corresponding breaker positions. Twist-outs can be removed by striking with a screwdriver and twisting back & forth with pliers.
  • The inner cover can be adjusted to fit snugly against breakers for flush mounting. Turn the two adjusting screws counter-clockwise to move the cover inward. Alternately, adjust each screw until the desired fit is achieved.

Q. Is a load center a panel?

A. A load center is also known as an electrical panel.

Q. Does a load center need a main breaker?

A. A load center can either be equipped with a main breaker or with a main lug only (MLO) design.

Product Variants

ProductModelPrice
EATON 3B4242ESN | BJ6NAK 3B4242ESN€11,092.60
RFQ
EATON 3BR1224B100S | BJ6NBE 3BR1224B100S€595.25
EATON 3BR1224BC100 | BJ6NBG 3BR1224BC100€657.21
EATON 3BR1224BC100R | BJ6NBH 3BR1224BC100R€781.43
EATON 3BR1224B100R | BJ6NBJ 3BR1224B100R€647.21
EATON 3BR1224B100 | BJ6NBK 3BR1224B100€559.72
EATON 3BR1224H100 | BJ6NBQ 3BR1224H100€848.17

Explore Products

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

EATON BR4242B400R Main Circuit Breaker Loadcenter, 400A, 42 Circuits, Single-Phase
€5,006.88 /unit