Flat Shipping

Flat Shipping at €24.99 + VAT

CONDOR SK R3/16 | AA4KUZ | 12T098 | Thermal Overload, 10 to 16A

CONDOR SK-R3/16 Thermal Overload Block, 10 To 16 A

Item: AA4KUZ Model: SK-R3/16Cross Ref: 12T098
In Stock

Get it by Monday, Nov 25

Flat Shipping at 24.99 + VAT €24.99 flat shipping is applicable on orders with an aggregate weight less than 10kg. Orders exceeding 10kg will be charged default shipping rates.

€49.09 /unit
Add To Cart
Request a Quote

Payment Options Available

Delivery Options Available

Product Specifications:

ItemThermal Overload, 10 to 16A
Amps10 to 16
HzNot Applicable
MaterialNot Specified
Phase3
Thread SizeNot Applicable
Tube SizeNot Applicable
TypeOverload Block
Voltage600 VAC

Shipping Info:

Ship weight (kg) 0.1195
Ship height (cm)12.7
Ship length (cm)12.7
Ship width (cm)12.7
HS code8536308000
Country of OriginDE

Product Details:

CondorSK-R3/16 thermal overload blocks are used with Condor MDR3 Series pressure switches for overload protection in 3 phase equipment, such as air compressors, mixers, elevators & conveyors. The contacts inside the thermal overload block open up based on the heat generated when the current flowing through the unit is high enough to cause damage to connected equipment. Overload may be caused due to fault in bearing, shaft coupling & motor drive setting or external factors like the improper power supply.

Features:

  • Condor SK-R3/16 3-Phase thermal overload block protects the equipment by cutting power if it draws excessive current for an extended time.
  • It can be adjusted to the desired current rating ranging from 10 to 16A.
  • This Condor SK-R3/16 thermal overload block has maximum voltage rating of 600VAC.
  • Raptor Supplies also offers Condor SK-R3/10 thermal overload having current rating range from 6.3 to 10A.

Compatible Accessories:

  • Condor MDR3 Series Pressure Switches: Condor SK-R3/16 thermal overload blocks are used to replace old, worn-out or faulty thermal overload parts of these pressure switches.

Standards and Approvals:

  • ISO 9001:2008

Frequently Asked Questions:

Q. How do you adjust a Condor MDR3 Series pressure switch?

    A.
  • Remove the casing of the pressure switch after disconnecting it from the equipment.
  • Turn the yellow disc on top of the thermal overload block to the desired current ratings.
  • The cut-in & cut-out pressure can be set by turning the calibrating screw on the relay clockwise (for increasing) or anti-clockwise (for decreasing).
  • The difference between cut-in & cut-out pressure or differential pressure can be adjusted using the screw next to the calibration screw.
  • Users can also replace old, faulty or worn-out thermal overload blocks, unloader valves & other parts.
  • Now that the pressure switch is set up, put the casing back on and connect it to the desired application.

Q. What is the use of a thermal overload block?

A. The thermal overload block protects the application from damage in case of a short circuit, over-load or overheating. Generally, the thermal overload relay gets activated by sensing heat caused by high current flow.

Product Variants

ProductModelAmpsHzItemPhaseThread SizeTube SizeTypeVoltagePkg. Qty.Price
CONDOR SK-3 Contact Block without On/Off MDR3 Series | AA4KUQ 12T090 SK-330Not ApplicableContact Block-Not ApplicableNot ApplicableStandard Replacement600 VAC1€38.16
CONDOR SK-3S Contact Block with Auto/Off MDR3 Series | AA4KUR 12T091 SK-3S30Not ApplicableContact Block with Auto/Off-Not ApplicableNot ApplicableStandard Replacement with Auto/Off600 VAC1€50.18
CONDOR SK-R3/1.0 Thermal Overload 0.63 to 1A 3-Phase MDR3 | AA4KUT 12T092 SK-R3/1.00.63 to 1Not ApplicableThermal Overload, 0.63 to 1A3Not ApplicableNot ApplicableOverload Block600 VAC1€45.79
CONDOR SK-R3/1.6 Thermal Overload 1 to 1.6A 3-Phase MDR3 | AA4KUU 12T093 SK-R3/1.61 to 1.6Not ApplicableThermal Overload, 1 to 1.6A3Not ApplicableNot ApplicableOverload Block600 VAC1€45.79
CONDOR SK-R3/2.5 Thermal Overload 1.6to 2.5A 3-Phase MDR3 | AA4KUV 12T094 SK-R3/2.51.6 to 2.5Not ApplicableThermal Overload, 1.6 to 2.5A3Not ApplicableNot ApplicableOverload Block600 VAC1€45.79
CONDOR SK-R3/4.0 Thermal Overload 2.5 to 4A 3-Phase MDR3 | AA4KUW 12T095 SK-R3/4.02.5 to 4Not ApplicableThermal Overload, 2.5 to 4A3Not ApplicableNot ApplicableOverload Block600 VAC1€45.79
CONDOR SK-R3/6.3 Thermal Overload 4 to 6.3A 3-Phase MDR3 | AA4KUX 12T096 SK-R3/6.34 to 6.3Not ApplicableThermal Overload, 4 to 6.3A3Not ApplicableNot ApplicableOverload Block600 VAC1€45.79

Explore Products

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

CONDOR SK-R3/16 Thermal Overload Block, 10 To 16 A
€49.09 /unit