EATON Bussmann Series HLE Fuses


Eaton Bussmann Series HLE fuses are high-speed, current-limiting fuses that protect power electronics equipment, including inverters, drives and rectifiers. These fuses are designed to prevent short circuits & overloads.

Filter
StyleModelPrice (ex. VAT)
A
15HLE-80E
€3,373.12
B
5HLE-100E
€2,382.36
A
15HLE-200E
€6,421.04
A
15HLE-30E
-
RFQ
A
15HLE-25E
€3,395.82
A
15HLE-50E
€3,373.12
A
15HLE-250E
€10,592.08
A
15HLE-65E
€3,373.12
B
5HLE-150E
€4,530.27
C
5HLE-15E
€2,382.36
C
5HLE-25E
€2,382.36
A
15HLE-125E
€6,421.04
C
5HLE-20E
€2,382.36
C
5HLE-30E
€2,382.36
B
5HLE-300E
€7,472.30
D
8HLE-20E
€2,866.40
E
8HLE-200E
€8,962.24
D
8HLE-150E
€5,403.80
D
8HLE-25E
€2,866.40
D
8HLE-50E
€2,866.40
C
8HLE-CL
€4,310.94
A
15HLE-175E
€6,421.04
A
15HLE-20E
€3,395.82
A
15HLE-CL
€6,114.73
B
5HLE-50E
€2,382.36
A
15HLE-40E
€3,373.12
C
5HLE-10E
€2,382.36
B
5HLE-200E
€4,530.27
C
5HLE-175E
€4,530.27
B
5HLE-125E
€4,530.27
B
5HLE-400E
€7,884.49
B
5HLE-250E
€4,530.27
B
5HLE-40E
€2,382.36
B
5HLE-350E
€7,472.30
B
5HLE-80E
€2,382.36
F
15HLE-10E
€3,373.12
B
5HLE-450E
€7,884.49
B
5HLE-65E
€2,382.36
D
8HLE-175E
€5,403.80
D
8HLE-30E
€2,866.40
D
8HLE-100E
€2,866.40
E
8HLE-250E
€8,962.24
D
8HLE-125E
€5,403.80
D
8HLE-40E
€2,579.01
A
15HLE-150E
€6,421.04
D
8HLE-80E
€2,866.40

Working Mechanism

  • When the current flowing through the circuit exceeds a certain level, the fuse element melts and interrupts the circuit.
  • This interruption prevents the current flow to the equipment and stops the flow of electricity.
  • The high-speed action of the fuse ensures that the interruption occurs quickly, reducing the risk of equipment damage or failure.
  • As a result, the equipment is protected from potential damage due to excessive current flow.

Features

  • They feature a single barrel design for reduced weight and enhanced performance.
  • These fuses can be operated in both indoor / outdoor environments.
  • They have an interrupt rating of 65kAIC for safe operations at rated voltage.

Standards and Approvals

  • IEEE

Frequently Asked Questions

What are the factors to consider while installing Eaton Bussmann Series HLE fuses?

  • Ensure that fuses are properly sized and rated for the specific application.
  • The installation should be carried out by the manufacturer's instructions and safety regulations.

How do I maintain these HLE fuses?

  • Regularly inspect Eaton Bussmann Series HLE fuses to ensure they are in good condition and functioning correctly.
  • Replace damaged or defective fuses immediately with new fuses of the same type and rating.
  • Store fuses in a cool & dry place to prevent exposure to moisture, dust and other contaminants.
  • Use proper tools, such as fuse pullers while installing or removing fuses.
  • Maintain a record of installation, inspection and replacement of fuses.

What is the difference between a fuse and a circuit breaker?

fuse is a small, replaceable device consisting a metal wire or filament that melts when it's overloaded, thus interrupting the electrical circuit. A circuit breaker, on the other hand, is an automatic device that uses a switch mechanism to interrupt the flow of current in the event of an overload or short circuit.

We are here to help!

Looking for a part not listed here?