ASCO VALVES Steam And Hot Water Solenoid Valves

Ideal for high-temperature fluid applications in laundries, moulding operations, steam atomisation and sterilisers. Can withstand temperatures up to 140 degrees F and feature high flow capacity

Filter

ASCO VALVES -

Hot Water Solenoid Valve

StyleModelCenter Line Pipe Center SizeCoefficient Of VolumeMin. Operating Pressure DifferentialOrifice Dia.Overall HeightOverall LengthOverall WidthPipe SizePrice (ex. VAT)
A8210G001HW2-13/16"35 psi5/8"3.375"2.75"2 9/32"3/8"€212.71
B8210G002HW2-13/16"45 psi5/8"3.375"2.75"2 9/32"1/2"€206.20
C8221G005HW3-9/16"5.55 psi3/4"4-5/16"2 23/32"3 29/64"3/4"€461.77
A8210G093HW3-9/32"30 psi5/8"3 27/32"2.75"2 16/64"3/8"€267.84
B8210G094HW3-9/32"40 psi5/8"3 27/32"2.75"2 16/64"1/2"€236.77
B8210G095HW3.437"50 psi3/4"4 3/32"2 13/16"2 9/32"3/4"€259.23
ASCO VALVES -

Steam Solenoid Valve

StyleModelCenter Line Pipe Center SizeCoefficient Of VolumeCoil Insulation ClassHzMin. Operating Pressure DifferentialOrifice Dia.Overall HeightOverall LengthPrice (ex. VAT)
A8222G0943-9/32"4F50/600 psi5/8"3 27/32"2.75"€412.59
B8222G0933-9/32"3F50/600 psi5/8"3 27/32"2.75"€476.31
C8267G0153-21/64"4.5H600 psi3/8"4-5/16"3 27/64"€508.02
C8267G0073-21/64"4.5H600 psi3/8"4-5/16"3.437"€538.71
C8267G0113-21/64"5.1H600 psi3/8"4-5/16"3 27/64"€508.02
C8267G0193-39/64"9.7H600 psi1/2"4 59/64"3 27/64"€683.38
C8267G0233-39/64"9.7H600 psi1/2"4 59/64"3 27/64"€683.38
A8222G0953.437"5F50/600 psi3/4"4 9/64"2 13/16"€398.33
D8222G0703.625"1.2H50/601 psi3/8"4 11/64"2 9/32"€336.41
D8222G0743.625"2.5H50/601 psi3/8"4 11/64"2 9/32"€327.98
D8222G0763.625"2.5H50/601 psi3/8"4 11/64"2 9/32"€382.69
D8222G0663.625"2.5F50/601 psi3/8"4 11/64"2 9/32"€312.30
D8222G0474-1/64"3.6H50/602 psi1/2"4 13/16"2.75"€420.75
D8222G0054-1/64"4.6H50/605 psi1/2"4 13/16"2.75"€528.36
D8222G0494-1/64"4.6H50/602 psi1/2"4 13/16"2.75"€477.98
E8222G0024-3/32"4H50/600 psi5/8"4 43/63"2.75"€701.36
E8222G0034-9/32"5H50/600 psi3/4"4 31/32"2 13/16"€794.21
ASCO VALVES -

Steam and Hot Water Solenoid Valve

StyleModelAmbient Temp. RangeCenter Line Pipe Center SizeCoefficient Of VolumeCoil EnclosureCoil Insulation ClassElectrical ConnectionsHzMin. Operating Pressure DifferentialPrice (ex. VAT)
AEF8220G025125 Degrees F4.187"13.5Explosionproof & WatertightH1/2" Conduit w/18" Leads50/605 psi€1,011.40
B8220G408125 Degrees F3.5"8.8Watertight No Junction BoxH1/2" Conduit w/18" Leads-0 psi€457.88
C8220G029125 Degrees F4-11/32"22.5Watertight No Junction BoxH1/2" Conduit w/18" Leads50/605 psi€1,288.54
C8220G027125 Degrees F4-3/32"15Watertight No Junction BoxH1/2" Conduit w/18" Leads50/605 psi€994.41
C8220G013125 Degrees F4.75"43Watertight No Junction BoxF1/2" Conduit w/18" Leads50/605 psi€1,434.43
C8220G011125 Degrees F4-11/32"22.5Watertight No Junction BoxF1/2" Conduit w/18" Leads50/605 psi€834.92
C8220G009125 Degrees F4-3/32"15Watertight No Junction BoxF1/2" Conduit w/18" Leads50/605 psi€633.96
D8220G095125 Degrees F4.5"5Watertight No Junction BoxH1/2" Conduit w/18" Leads605 psi€647.67
E8220G410125 Degrees F4.187"11.5Watertight No Junction BoxF1/2" Conduit w/18" Leads50/605 psi€577.50
FEF8220G406120/60125 Degrees F3-17/32"4.7Explosionproof & WatertightH1/2" Conduit w/18" Leads50/605 psi€476.56
GSU8220G406125 Degrees F3-17/32"4.7Watertight No Junction BoxHDIN50/605 psi€429.98
B8220G407125 Degrees F3-17/32"8.8Watertight No Junction BoxF1/2" Conduit w/18" Leads50/605 psi€261.69
B8220G405125 Degrees F3-17/32"4.7Watertight No Junction BoxH1/2" Conduit w/18" Leads-0 psi€423.23
H8220G409125 Degrees F3.5"8.8Watertight No Junction BoxH1/2" Conduit w/18" Leads50/605 psi€439.99
B8220G404125 Degrees F3-13/32"4.7Watertight No Junction BoxF1/2" Conduit w/18" Leads50/605 psi€258.77
B8220G402125 Degrees F3-17/32"4.4Watertight No Junction BoxH1/2" Conduit w/18" Leads-0 psi€423.23
B8220G401125 Degrees F3-13/32"4.4Watertight No Junction BoxF1/2" Conduit w/18" Leads50/605 psi€248.90
C8220G031125 Degrees F4.75"43Watertight No Junction BoxH1/2" Conduit w/18" Leads50/605 psi€1,677.60
I8263H300131 Degrees F2.5930.52Watertight No Junction BoxH1/2" Conduit w/18" Leads50/600 psi€246.73
J8263H305131 Degrees F2-9/16"0.52Watertight No Junction BoxH1/2" Conduit w/18" Leads50/600 psi€253.44
B8220G409140 Degrees F3.5"8.8Watertight No Junction BoxH1/2" Conduit w/18" Leads50/605 psi€462.66
B8220G406140 Degrees F3-17/32"4.7Watertight No Junction BoxH1/2" Conduit w/18" Leads50/605 psi€369.28
B8220G403140 Degrees F3-17/32"4.4Watertight No Junction BoxH1/2" Conduit w/18" Leads50/605 psi€331.49
E8220G411140 Degrees F4.187"11.5Watertight No Junction BoxH1/2" Conduit w/18" Leads50/605 psi€1,009.61
ASCO VALVES -

Slow Close HW Solenoid 1/2 inch NC Brass

ModelItemPrice (ex. VAT)
8221G003HWAD7HRE€424.45
ASCO VALVES -

Slow Close HW Solenoid 1 inch NC Brass

ModelItemPrice (ex. VAT)
8221G007HWAE4MKR€938.36

Features

Red Hat Steam Solenoid Valves

  • They feature brass construction for structural rigidity and can be operated at differential pressures down to 5 psi.
  • These valves have normally closed valves for emergency safety while the system is over-pressurised.
  • They operate on a voltage of 120 VAC.
  • These hot water solenoid valves are available in pipe sizes of 1/4, 3/8, 1/2 and 3/4 inches.

ASCO Numatics Steam Solenoid Valves

  • ASCO Numatics provides steam solenoid valves with NPTF ports to ensure secure and stable connections that are resistant to vibrations. Users searching for reliable and high-quality steam solenoid valves can explore ASCO Numatics, a reputable steam solenoid valves supplier, for their application.
  • These hot water solenoid valves feature brass construction for resisting corrosion on exposed surfaces.
  • They are compatible with hot water and steam.
  • These steam solenoid valves have floating PTFE Diaphgram for providing a tight seal and low friction properties.
  • They have threaded bonnet for reducing downtime while inspection and maintenance.